0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
G6B-2014P-US DC5

G6B-2014P-US DC5

  • 厂商:

    OMRON(欧姆龙)

  • 封装:

    DIP6

  • 描述:

    G6B-2014P-US DC5

  • 数据手册
  • 价格&库存
G6B-2014P-US DC5 数据手册
G6B PCB Power Relay High Capacity and High Dielectric Strength Miniature Relay with Fully Sealed Construction in 5 A (8 A) SPST-NO(1a), SPST-NO+SPST-NC(1a1b), DPST-NO(2a), DPST-NC(2b) Types • P6B model for connecting sockets are available. • High insulation with dielectric strength of 3,000VAC between coil and contacts (impulse withstand voltage of 6 kV). G 6 B • Standard model conforms to UL/CSA standards. • AgSnIn contacts suitable for loads that generate surge voltage (inductive load, capacity load, etc.) are available. (-FD type) • Ultrasonic cleanable models are available. (-U type) • Operation indicator & built-in surge absorption diode models are available. (-ND type) • 2-Pole type available. • High-reliability models are available. G6B-1184P-US model (The relay used in Terminal Relay G6B-48BND) ■Application Examples RoHS Compliant • Ideal for output applications of control equipments ■Model Number Legend G6B @ - @ @ @ @ @ -@ - @ -@ - @ -@ - @ 1 2 3 4 5 6 7 1. Relay Function None: Single-side stable U : Single-winding latching (G6B@-1114 models only) K : Double-winding latching (G6B@-1114 models only) 2. Contact Form 21: SPST-NO + SPST-NC 22: DPST-NO 20: DPST-NC 11: SPST-NO 3. Classification 1: Standard 7: High-capacity 8: Single crossbar 8 9 10 11 4. Enclosure rating 4: Fully sealed 7: Flux protection 5. Terminal Shape P: Straight PCB terminals Socket mounting terminals C: Self-clinching PCB 6. Contact material None: Standard (Ag-alloy (Cd free)) FD : AgSnIn contact (Suitable for DC inductive load with high inrush current) 7. Coil Polarity None: 5, 6 Terminal (+), 1, 2 Terminal (-) 1 : 5, 6 Terminal (-), 1, 2 Terminal (+) 8. Operation Indicator Diode Availability None: Standard ND : Operation indicator & coil surge absorption diode (for -1177 type only) 9. Approved Standards US: UL/CSA 10. Washability None: Standard U : For ultrasonically cleanable 11. Mounting None: Mounted directly to PCB P6B : Mounted to Socket 1 G6B PCB Power Relay ■Ordering Information ● Standard Models (UL, CSA certified) Number of poles Contact material Relay Function Contact form SPST-NO (1a) (Standard) Single-side stable SPST-NO (1a) (High-capacity) SPST-NO (1a) (High-reliability ) 1-pole Straight PCB Standard (Ag-alloy (Cd free)) Model 5, 6, 12, 24 VDC Self-clinching G6B-1114C-US PCB 5, 6, 12, 24 VDC G6B-1114C-FD-US 12, 24 VDC Straight PCB 5, 6, 12, 24 VDC G6B-1174P-FD-US 5, 6, 12, 24 VDC Self-clinching G6B-1174C-US PCB 5, 12, 24 VDC G6B-1174C-FD-US 5, 12, 24 VDC Straight PCB 5, 12, 24 VDC Self-clinching PCB Straight PCB G6B-1174P-US G6B-1184P-US --G6BU-1114P-US SPST-NO (1a) (Standard) Single-side stable SPST-NO (1a) Straight PCB G6B-1177P-ND-US (Built-in highcapacity operation Self-clinching G6B-1177C-ND-US indicator & diode) PCB DPST-NO (2a) (Standard) DPST-NC (2b) (Standard) Minimum Rated coil voltage packing unit G6B-1114P-FD-US Double-winding latching Single-side stable AgSnIn contact Model 5, 6, 12, 24 VDC SPST-NO (1a) (Standard) SPST-NO (1a)+ SPST-NC (1b) (Standard) Rated coil voltage G6B-1114P-US Single-winding latching G 6 B 2-pole Terminals --5, 6, 12, 24 VDC --- --- --- --- G6BU-1114P-FD-US 12 VDC Straight PCB G6BK-1114P-US 5, 6, 12, 24 VDC G6BK-1114P-FD-US 5, 6, 12, 24 VDC Self-clinching G6BK-1114C-US PCB 5, 6, 12, 24 VDC G6BK-1114C-FD-US 24 VDC 5, 12, 24 VDC G6B-1177P-FD-ND-US 5, 12, 24 VDC 5, 12, 24 VDC G6B-1177C-FD-ND-US 12, 24 VDC G6B-2114P-US --- --- 5, 6, 12, 24 VDC G6B-2114P-FD-US 5, 6, 12, 24 VDC Self-clinching G6B-2114C-US PCB 5, 12, 24 VDC G6B-2114C-FD-US 5, 12 VDC Straight PCB G6B-2214P-US 20 pcs/tube 5, 12, 24 VDC Self-clinching G6BU-1114C-US PCB Straight PCB 100 pcs/tray 5, 6, 12, 24 VDC G6B-2214P-FD-US 5, 6, 12, 24 VDC Self-clinching G6B-2214C-US PCB 5, 12, 24 VDC G6B-2214C-FD-US 5, 12, 24 VDC Straight PCB G6B-2014P-US 5, 6, 12, 24 VDC G6B-2014P-FD-US 5, 6, 12, 24 VDC Self-clinching G6B-2014C-US PCB 5, 6, 12, 24 VDC G6B-2014C-FD-US 12, 24 VDC 100 pcs/tray Note: AgSnIn contact models are highly welding-resistant, and roughening of contacts due to inrush current and inductive load is lessened. ● Models for Reverse Coil Polarity Number of poles Contact material Relay Function Contact form SPST-NO (1a) (Standard) Single-side stable SPST-NO (1a) (High-capacity) 1-pole 2-pole Single-winding latching SPST-NO (1a) (Standard) Double-winding latching SPST-NO (1a) (Standard) Single-side stable SPST-NO (1a)+ SPST-NC (1b) (Standard) DPST-NO (2a) (Standard) Terminals Straight PCB Self-clinching PCB Straight PCB Self-clinching PCB Straight PCB Self-clinching PCB Straight PCB Self-clinching PCB Straight PCB Self-clinching PCB Straight PCB Self-clinching PCB Standard (Ag-alloy (Cd free)) Model G6B-1114P-1-US --G6B-1174P-1-US --G6BU-1114P-1-US --G6BK-1114P-1-US --G6B-2114P-1-US --G6B-2214P-1-US --- Rated coil voltage 5, 6, 12, 24 VDC --- AgSnIn contact Model G6B-1114P-FD-1-US Minimum Rated coil voltage packing unit 24 VDC --- --- --- --- --- --- --- --- --- --- --- 5, 6, 12, 24 VDC --- --- --- --- --- 5, 12, 24 VDC --5, 12 VDC 5, 6, 12, 24 VDC --5, 12, 24 VDC --- G6B-2114P-FD-1-US 12, 24 VDC --- --- --- --- --- --- Note: AgSnIn contact models are highly welding-resistant, and roughening of contacts due to inrush current and inductive load is lessened. 2 100 pcs/tray 20 pcs/tube 100 pcs/tray G6B PCB Power Relay ● Models for Ultrasonically Cleanable Number of poles 1-pole Contact material Relay Function Contact form Single-side stable SPST-NO (1a) (Standard) Single-winding latching SPST-NO (1a) (Standard) Double-winding latching SPST-NO (1a) (Standard) SPST-NO (1a)+ SPST-NC (1b) (Standard) 2-pole Single-side stable DPST-NO (2a) (Standard) DPST-NC (2b) (Standard) Terminals Straight PCB Standard (Ag-alloy (Cd free)) Model Rated coil voltage G6B-1114P-US-U 5, 6, 12, 24 VDC AgSnIn contact Model G6B-1114P-FD-US-U Minimum Rated coil voltage packing unit 6, 12, 24 VDC Self-clinching G6B-1114C-US-U PCB 5, 12, 24 VDC --- --- Straight PCB 24 VDC --- --- --- --- --- 5, 6, 12, 24 VDC G6BK-1114P-FD-US-U Self-clinching PCB Straight PCB G6BU-1114P-US-U --G6BK-1114P-US-U Self-clinching G6BK-1114C-US-U PCB 24 VDC Straight PCB 5, 12, 24 VDC Self-clinching PCB Straight PCB G6B-2114P-US-U --- G6B-2114P-FD-US-U --- G6B-2214P-US-U 5, 6, 12, 24 VDC Self-clinching G6B-2214C-US-U PCB 12, 24 VDC Straight PCB 5, 12, 24 VDC Self-clinching PCB --- G6B-2014P-US-U --- --G6B-2214P-FD-US-U --G6B-2014P-FD-US-U --- --- 12, 24 VDC --5, 12, 24 VDC 100 pcs/tray --5, 12, 24 VDC --5, 12, 24 VDC --- Note: When ordering, add the rated coil voltage to the model number. Example: G6B-1114P-US DC5 Rated coil voltage However, the notation of the coil voltage on the product case as well as on the packing will be marked as @@ VDC. G 6 B ● Connecting Sockets (Sold Separately) Applicable relay Model G6B-1114P(-FD)-US-P6B G6B-1174P(-FD)-US-P6B G6B-1177P(-FD)-ND-US-P6B G6BU-1114P-US-P6B P6B-04P G6BK-1114P-US-P6B P6B-06P G6B-2114P-US-P6B G6B-2214P-US-P6B G6B-2014P-US-P6B P6B-26P Removal Tool P6B-Y1 Hold-down Clips P6B-C2 Minimum ordering unit 20 pcs 1 pcs Note 1. G6B-1174P-US-P6B and G6B-1177P-ND-US-P6B are rated for 8 A when mounted on a PCB. However, when used with the P6B-04P socket models, the allowable current is derated to 5 A. 2. The P6B sockets are designed to be used with G6B-@@@@P(-FD)-US-P6B relays. Only use G6B relays that include "-P6B" in their model numbers with the sockets. Do not use standard G6B's that omit "-P6B" from their model numbers with the sockets. 3. The hold-down clips of the P6B-C2 model are not suitable for the G6B-1174P and G6B-1177P models since they have different heights. 4. Products with UL/CSA certification marks will be supplied for orders of standard models. 3 G6B PCB Power Relay ■Ratings ● Coil: 1-Pole, Single-side Stable Type (Including models for ultrasonically cleanable) Item Rated voltage Rated current Coil resistance (mA) (Ω) 5 VDC 40 125 6 VDC 33.3 180 12 VDC 16.7 720 24 VDC 8.3 2,880 Must operate Must release voltage (V) voltage (V) Max. voltage Power consumption (V) (mW) % of rated voltage 70% max. 160% (at 23°C) 10% min. Approx. 200 ● Coil: 2-Pole, Single-side Stable Type (Including models for ultrasonically cleanable) Item Rated voltage Rated current Coil resistance (mA) (Ω) 5 VDC 60 6 VDC 50 120 12 VDC 25 480 24 VDC 12.5 Must operate Must release voltage (V) voltage (V) Max. voltage Power consumption (V) (mW) % of rated voltage 83.3 80% max. 140% (at 23°C) 10% min. Approx. 300 1,920 ● Coil: Single-winding Latching Type (Including models for ultrasonically cleanable) Item Rated current (mA) Rated voltage G 6 B Coil resistance (Ω) 5 VDC 40 125 6 VDC 33.3 180 12 VDC 16.7 720 24 VDC 8.3 2,880 Must set Must reset Max. voltage voltage (V) voltage (V) (V) % of rated voltage 70% max. Power consumption Set coil (mW) Reset coil (mW) 200 200 160% (at 23°C) 70% max. ● Coil: Double-winding Latching Type (Including models for ultrasonically cleanable) Rated current (mA) Item Rated voltage Set coil Must set voltage Must reset voltage Max. voltage (V) (V) (V) Coil resistance (Ω) Reset coil Set coil Reset coil 5 VDC 56 56 89.2 89.2 6 VDC 46.8 46.8 128.5 128.5 12 VDC 23.3 23.3 515 515 24 VDC 11.7 11.7 2,060 2,060 % of rated voltage 70% max. 130% (at 23°C) 70% max. Power consumption Set coil (mW) Reset coil (mW) 280 280 ● Coil: Operation Indicator Model (Flux-resistant type. Do not wash down with water.) Item Rated voltage Rated current Coil resistance (mA) (Ω) 43 116 12 VDC 5 VDC 19.7 610 24 VDC 11.3 2,120 Must operate Must release voltage (V) voltage (V) Max. voltage Power consumption (V) (mW) % of rated voltage 70% max. 10% min. 130% (at 23°C) Approx. 200 Approx. 240 Approx. 275 Note 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%. 2. The operating characteristics are measured at a coil temperature of 23°C. 3. The “Max. voltage” is the maximum voltage that can be applied to the relay coil. ● Contacts Model Load Item G6B-1114P(-FD)(-1)-US G6BU-1114P(-FD)(-1)-US G6BK-1114P(-FD)(-1)-US G6B-1114C(-FD)-US G6BU-1114C-US G6BK-1114C(-FD)-US Resistive load Inductive load (cosφ = 0.4; L/R = 7 ms) Contact type Contact material Rated load Rated carry current G6B-1174P(-FD)(-1)-US G6B-1177P(-FD)-ND-US G6B-1174C(-FD)-US G6B-1177C(-FD)-ND-US Resistive load Inductive load (cosφ = 0.4; L/R = 7 ms) Resistive load Inductive load (cosφ = 0.4; L/R = 7 ms) Single crossbar Single Au-alloy + Ag (Cd free) Ag-Alloy (Cd free) 2 A at 250 VAC 2 A at 30 VDC 8 A (5 A) 0.5 A at 250 VAC 5 A (3 A) at 250 VAC 1.5 A (1.5 A) at 250 VAC 0.5 A at 30 VDC 5 A (3 A) at 30 VDC 1.5 A (1.5 A) at 30 VDC 2A 5 A (5 A) 2A 5 A (5 A) 380 VAC, 125 VDC 5 A (5 A) 8 A (5 A) Note 1. The values in the parentheses ( ) are for -FD models only. 2. Use the -FD type for inductive load and switching load which contact roughening is small. 4 Inductive load (cosφ = 0.4; L/R = 7 ms) Single Max. switching voltage Max. switching current Resistive load Ag-Alloy (Cd free) 5 A (3 A) at 250 VAC 2 A (2 A) at 250 VAC 8 A (5 A) at 250 VAC 2 A (2 A) at 250 VAC 5 A (3 A) at 30 VDC 2 A (2 A) at 30 VDC 8 A (5 A) at 30 VDC 2 A (2 A) at 30 VDC 5 A (5 A) G6B-1184P-US G6B-2114P(-FD)(-1)-US G6B-2214P(-FD)(-1)-US G6B-2014P(-FD)-US G6B-2114C(-FD)-US G6B-2214C(-FD)-US G6B-2014C(-FD)-US G6B PCB Power Relay ■Characteristics G6B-1114P(-FD)(-1)-US G6B-1174P(-FD)(-1)-US Model G6B-1114C(-FD)-US G6B-1174C(-FD)-US Item Classification G6BU-1114P(-FD)(-1)-US G6BU-1114C-US G6BK-1114P(-FD)(-1)-US G6BK-1114C(-FD)-US G6B-1177P(-FD)-ND-US G6B-1177C(-FD)-ND-US G6B-1184P-US G6B-2114P(-FD)(-1)-US G6B-2214P(-FD)(-1)-US G6B-2014P(-FD)(-1)-US G6B-2114C(-FD)-US G6B-2214C(-FD)-US G6B-2014C(-FD)-US Single-winding Double-winding Built-in operation indicator Single-side stable Single-side stable latching latching & surge absorption diode 30 mΩ max. 50 mΩ max. 30 mΩ max. 10 ms max. 10 ms max. − 15 ms (at 23°C) − − 15 ms (at 23°C) − 1,000 MΩ min. 2,000 VAC, 3,000 VAC, 50/60 Hz for 1 min 3,000 VAC, 50/60 Hz for 1 min 50/60 Hz for 1 min Single-side stable Contact resistance *1 Operate (set) time Release (reset) time Min. set pulse width Min. reset pulse width Insulation resistance *2 Between coil and contacts Between contacts Dielectric of the same polarity strength Between contacts of different polarity Between set and − reset coils Impulse withstand voltage 6 kV 1.2 × 50 μs (between coil and contacts) Destruction Vibration resistance Malfunction Destruction Shock resistance Malfunction 100 m/s2 Mechanical Durability Electrical Failure rate (P level) (reference value) *3 Ambient operating temperature Ambient operating humidity Weight Approx. 3.5 to 4.6 g 1,000 VAC, 50/60 Hz for 1 min 2,000 VAC, 50/60 Hz for 1 min − 250 VAC, 50/60 Hz for 1 min 4.5 kV 1.2 × 50 μs − 6 kV 1.2 × 50 μs − 6 kV 1.2 × 50 μs 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude) 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude) 1,000 m/s2 300 m/s2 100 m/s2 50,000,000 operations min. (at 18,000 operations/hr) 100,000 operation min. (at 1,800 operations/hr under rated load) 10 mA at 5 VDC Approx. 3.5 g -25°C to 70°C (with no icing or condensation) 5% to 85% Approx. 3.7 g Approx. 5.4 g G 6 B 1 mA at 1 VDC 10 mA at 5 VDC Approx. 3.5 g Approx. 4.5 g Note 1. The values here are initial values. 2. The G6B-1177P(-FD)-ND model is flux-resistant. Do not wash it down with water. *1. The contact resistance was measured with 1 A at 5 VDC using a voltage-drop method. *2. Measurement conditions: The insulation resistance was measured with a 500 VDC megohmmeter at the same locations as the dielectric strength was measured.(Except the location between set/reset coil) *3. This value was measured at a switching frequency of 120 operations/min. 5 G6B PCB Power Relay ■Engineering Data 20 AC resistive load 5 3 2 50 30 AC resistive load 10 8 5 AC inductive load cosφ = 0.4 DC inductive load (L/R = 7 ms) 1 100 3 2 DC resistive load 0.5 0.3 0.1 0.1 3 5 10 20 30 100 300 500 3 5 10 30 50 100 Durability (x104 operations) Durability (x104 operations) 300 G6B-1174P-FD-US 250 VAC/30 VDC resistive load 100 G6B-1174P-US 250 VAC/30 VDC resistive load 50 30 AC inductive load (cosφ = 0.4) AC resistive load AC resistive load DC resistive load DC inductive load (L/R = 7 ms) 380 0 1,000 3 5 10 30 50 100 Switching voltage (V) 1,000 G6B-2114P(-FD)-US 500 G6B-2214P(-FD)-US 300 G6B-2014P(-FD)-US 250 VAC/30 VDC inductive load (cosφ = 0.4, L/R = 7 ms) 100 G6B-2114P-US G6B-2214P-US G6B-2014P-US 250 VAC/30 VDC resistive load 50 30 300 500 1,000 Switching voltage (V) ● Ambient Temperature vs. Maximum Coil Voltage G6B-1114P-US G6B-2114P-US G6B-1174P-US G6B-2214P-US G6B-1174P-FD-US G6B-2014P-US G6B-2114P(-FD)-US G6B-2214P(-FD)-US G6B-2014P(-FD)-US G6B-1114P-US 250 VAC/30 VDC resistive load 500 10 0.1 0 1,000 200 180 G6B-1114P-US G6B-1174P-US G6B-1174P-FD-US 160 140 130 120 10 110 10 5 G6B-1114P-US G6B-1174P-FD-US 3 G6B-1174P-US 250 VAC/30 VDC inductive load (cosφ = 0.4, L/R = 7 ms) 1 0 1 2 3 4 5 6 G6B-2114P-FD-US G6B-2214P-FD-US G6B-2014P-FD-US 250 VAC resistive load 5 3 80 1 7 G6B-2114P-US G6B-2214P-US G6B-2014P-US 100 Higher capacity 8 9 10 60 0 1 1.5 2 3 4 5 Switching current (A) 6 7 8 9 10 0 20 23 30 40 50 60 70 80 90 Ambient temperature (°C) Switching current (A) Note: The maximum coil voltage refers to the maxi-mum value in a varying range of operating power voltage, not a continuous voltage. 2.54 mm max. X min. Sample 60 De-energized max. 40 Sample X min. 20 Energized −20 0 20 40 60 80 Ambient temperature (°C) 6 Change rate on the basis of initial value (%) Must operate voltage Must release voltage 80 0 −40 G6B-1114P-US Must operate voltage Must release voltage Must operate voltage Must release voltage +1.0 Initial stage Test Change rate on the basis of initial value (%) Sample: G6B-1114P-US Number of Relays: 5 pcs G6B-1114P-US Change rate on the basis of initial value (%) 100 ● Mutual Magnetic Interference +0.5 2.54 mm 0 −0.5 −1.0 +1.0 Average value Sample De-energized Initial stage Test +0.5 Sample 0 −0.5 −1.0 Average value Energized Initial stage +1.0 Test +0.5 0 −0.5 −1.0 Average value Initial stage Change rate on the basis of initial value (%) ● Ambient Temperature vs. Must Operate and Must Release Voltage G6B-1114P-US Must-operate/must-release voltage (%) G 6 B G6B-2114P-FD-US G6B-2214P-FD-US G6B-2014P-FD-US 0.3 Switching voltage (V) ● Durability G6B-1114P-US G6B-1174P-US G6B-1174P-FD-US 30 0.5 DC inductive load Maximum coil voltage (%) 0 50 3 2 1.5 1 AC inductive load 1 0.3 0.2 100 5 DC resistive load 0.5 Switching current (A) 40 10 G6B-2114P-US G6B-2214P-US G6B-2014P-US G6B-1174P-US Switching current (A) Switching current (A) ● Maximum Switching Current G6B-1114P-US G6B-1174P-FD-US +1.0 Test +0.5 0 −0.5 −1.0 Average value G6B PCB Power Relay ● Shock Malfunction Y 1,000 Y Energized Y Energized Reset 1,000 Set 300 X 400 X 1,000 Z 100 200 Z 1,000 700 600 200 100 400 X' 300 Z' X 1,000 Z 1,000 300 1,000 Z' 1,000 X' 1,000 Z' 1,000 X' 300 Unit: m/s2 1,000 Y' Y' Y' 1,000 Y' Unit: m/s2 Sample: G6B-1174P-US G6B-1174P-FD-US Test Conditions: Shock is applied in ±X, ±Y, and ±Z directions three times each with without energizing the Relays Shock direction X X' to check the number of Y malfunctions. Z Requirement: None Z' malfuction 100 m/s2 Sample: G6B-1114P-US Number of Relays: 12 pcs Test Conditions: Shock is applied in ±X, ±Y, and ±Z directions three times each with without energizing the Relays Shock direction X X' to check the number of Y malfunctions. Z Requirement: None Z' malfuction 100 m/s2 Y' (Coil) Unit: m/s2 Sample: G6BK-1114P-US Number of Relays: 12 pcs Test Conditions: The value at which malfunction occurred was measured after applying shock to the Shock direction X X' test piece 3 times each Y in 6 directions along 3 Z axes. Z' Standard value: 300 m/s2 Y' (Coil) (Coil) Sample: G6B-1114P-US G6B-1174P-FD-US Number of Relays: 10 pcs 30 Test: the variation of operating voltage is measured based on cold start at 23°C, during which rated voltage is applied to the coil with rated 20 contact current (5A), and left for 1 hour each under different ambient temperatures. 120% applied 10 40 Sample: G6B-1174P-US Test: the variation of operating voltage is measured 30 based on cold start at 23°C, during which rated voltage is applied to the coil with rated contact current (8A), and left for 1 hour each under different ambient 20 temperatures. 120% applied 110% applied 10 110% applied 0 −20 0 20 40 60 120% applied 0 −10 −10 −20 −50 80 100 −40 −20 0 20 40 60 −20 −50 80 100 110% applied 100% applied −40 −20 0 20 Ambient temperature (°C) Ambient temperature (°C) G 6 B 10 0 100% applied −40 40 Sample: G6B-2114P-US G6B-2214P-US G6B-2014P-US 30 Test: the variation of operating voltage is measured based on coil cold start at 23°C, during which rated voltage is applied to the coil with rated 20 contact current (5A), and left for 1 hour each under different ambient temperatures. 100% applied −10 −20 −50 Rate of variability (%) 40 Rate of variability (%) Rate of variability (%) ● Hot Start 40 60 80 100 Ambient temperature (°C) ■Dimensions (Unit: mm) 1-pole Single-side Stable Models (SPST-NO(1a)) Straight PCB G6B-1114P(-FD)(-1)-US 10 max. G6B-1184P-US 10 max. (9.8)* (9.8)* 0.3 3.5 0.85 0.9 0.5 0.9 PCB Mounting Holes (BOTTOM VIEW) Tolerance: ±0.1 mm 0.5 20 max. (19.9)* 2.54 * Average value Dimensions in pointed brackets < > are for the Relay mounted to Socket. Terminal Arrangement/ Internal Connections (BOTTOM VIEW) Four, 1.1-dia. holes 2.54 (1.2) 1 3 Self-clinching PCB G6B-1114C(-FD)-US 4 6 10.16 10 max. (9.8)* 10 max. (9.8)* 0.3 (1.1) (1.0) 3.2 7.62 Note: Check carefully the coil polarity of the Relay. Polarity in the parenthesis is the models for reverse coil polarity. Note: Orientation marks are indicated as follows: 3.5 0.85 0.9 0.5 (0.8) 0.5 0.9 20 max. (19.9)* * Average value 7 G6B PCB Power Relay 1-pole Single-side Stable Models (SPST-NO(1a)) Straight PCB G6B-1174P(-FD)(-1)-US 10 max. (9.9)* 12.5 max. (12.45)* 0.65 3.5 PCB Mounting Holes (BOTTOM VIEW) Tolerance: ±0.1 mm 0.85 0.9 0.45 0.9 Terminal Arrangement/ Internal Connections (BOTTOM VIEW) 0.5 20.2 max. (20.0)* 2.54 Four, 1.1-dia. holes * Average value Dimensions in pointed brackets < > are for the Relay mounted to Socket. 2.54 (1.2) 1 3 Self-clinching PCB G6B-1174C(-FD)-US 4 6 10 max. (9.9)* 10.16 7.62 (1.2) 12.5 max. (12.45)* 0.65 (1.0) 3.2 Note: Check carefully the coil polarity of the Relay. Polarity in the parenthesis is the models for reverse coil polarity. Note: Orientation marks are indicated as follows: 3.5 0.85 0.9 0.45 (0.8) 0.5 0.9 20.2 max. (20.0)* * Average value 1-pole Single-winding Latching Model (SPST-NO(1a)) G Straight PCB 6 G6BU-1114P(-1)-US B 10 max. (9.8)* 10 max. (9.8)* 0.3 3.5 PCB Mounting Holes (BOTTOM VIEW) Tolerance: ±0.1 mm 0.85 0.9 0.5 0.5 0.9 20 max. (19.9)* Terminal Arrangement/ Internal Connections (BOTTOM VIEW) 2.54 * Average value Dimensions in pointed brackets < > are for the Relay mounted to Socket. Four, 1.1-dia. holes 2.54 (1.2) 1 3 S R 4 6 Self-clinching PCB G6BU-1114C-US 10 max. (9.8)* 10.16 7.62 (1.1) 10 max. (9.8)* 0.3 (1.0) Note: Orientation marks are indicated as follows: 3.2 3.5 0.85 0.9 0.5 (0.8) 0.5 0.9 20 max. (19.9)* * Average value 1-pole Double-winding Latching Model (SPST-NO(1a)) Straight PCB G6BK-1114P(-FD)(-1)-US 10 max. (9.8)* 10 max. (9.8)* 0.3 PCB Mounting Holes (BOTTOM VIEW) Tolerance: ±0.1 mm 3.5 0.85 0.85 0.5 0.9 Note: Check carefully the coil polarity of the Relay. Polarity in the parenthesis is the models for reverse coil polarity. S: Set coil R: Reset coil 0.9 0.5 2.54 20 max. (19.9)* Terminal Arrangement/ Internal Connections (BOTTOM VIEW) Six, 1.1-dia. holes * Average value 2.54 Dimensions in pointed brackets < > are for the Relay mounted to Socket. (1.2) 1 6 Self-clinching PCB G6BK-1114C(-FD)-US 10 max. (9.8)* 2.54 7.62 7.62 (1.1) 10 max. (9.8)* 0.3 (1.0) 0.85 0.5 8 0.85 0.9 20 max. (19.9)* 0.9 R 3 (0.8) 0.5 * Average value 4 5 Note: Check carefully the coil polarity of the Relay. Polarity in the parenthesis is the models for reverse coil polarity. S: Set coil R: Reset coil Note: Orientation marks are indicated as follows: 3.2 3.5 2 S G6B PCB Power Relay 1-pole Single-side stable Models (SPST-NO (1a)) (Built-in high capacity operation indicator & surge absorption diode) Straight PCB 20.2 max. 0.45 G6B-1177P(-FD)-ND-US (20)* 3.7 1.7 10 max. (9.9)* 1.6 LED 0.3 15 max. (14.8)* 0.65 3.5 Terminal Arrangement/ Internal Connections (BOTTOM VIEW) PCB Mounting Holes (BOTTOM VIEW) Tolerance: ±0.1 mm 0.85 0.9 10.16 0.9 0.5 Four, 1.1-dia. holes 2.54 7.62 7.62 * Average value Dimensions in pointed brackets < > are for the Relay mounted to Socket. Self-clinching PCB G6B-1177C(-FD)-ND-US 1 3 2.54 4 7.62 6 (1.2) 0.45 20.2 max. (20)* (1.11) 10.16 3.7 Note: The G6B-1177P-ND-US model has a flux-resistant construction. Do not wash it down with water. Pay attention to the polarity of the coil since the LED and surge absorption diode are built-in. 1.7 10 max. (9.9)* 1.6 7.62 Note: Check carefully the coil polarity of the Relay. G 6 B LED 0.3 15 max. (14.8)* 0.65 (1.0) 3.2 3.5 0.85 0.9 10.16 (0.8) 0.5 0.9 7.62 7.62 * Average value 2-poles Single-side stable Models (SPST-NO (1a) + SPST-NC (1b), DPST-NO (2a), DPST-NC(2b)) Straight PCB 20 max. (19.9)* G6B-2114P(-FD)(-1)-US G6B-2214P(-FD)(-1)-US 11 max. (10.9)* G6B-2014P(-FD)-US PCB Mounting Holes (BOTTOM VIEW) Tolerance: ±0.1 mm Terminal Arrangement/ Internal Connections (BOTTOM VIEW) 11 max. (10.9)* Six, 1.1-dia. holes 2.54 3.5 G6B-2114 0.9 10.16 0.4 2.54 7.62 7.62 1 3 4 8 6 5 7.62 * Average value Dimensions in pointed brackets < > are for the Relay mounted to Socket. (1.7) (1.11) Self-clinching PCB G6B-2114C(-FD)-US G6B-2214C(-FD)-US G6B-2014C(-FD)-US 20 max. (19.9)* 10.16 7.62 G6B-2014 1 3 4 8 6 5 11 max. (10.9)* G6B-2214 11 max. (10.9)* (1.0) 3.2 3.5 7.62 3 4 8 6 5 Note: Check carefully the coil polarity of the Relay. Polarity in the parenthesis is the models for reverse coil polarity. (0.8) 0.3 0.8 10.16 1 7.62 * Average value 9 G6B PCB Power Relay ■Connecting Sockets Dimensions Socket for 1-pole Single-winding Latching Model and Single-side Stable Model 23.2 max. P6B-04P PCB Mounting Holes (BOTTOM VIEW) Tolerance: ±0.1 mm (23)* 10 max. (9.9)* Four, 1.1-dia. holes 2.54 3.1 2.54 (1.2) 10.1 max. (10)* 7 (2.71) 3.5 0.8 10.16 10.16 7.62 0.4 7.62 7.62 * Average value Socket for 1-pole Double-winding Latching Model P6B-06P 23.2 max. PCB Mounting Holes (BOTTOM VIEW) Tolerance: ±0.1 mm (23)* 10 max. (9.9)* 3.1 Six, 1.1-dia. holes 2.54 2.54 G 6 B (1.2) 10.1 max. (10)* 7 3.5 (2.71) 0.8 2.54 7.62 7.62 7.62 7.62 2.54 0.4 7.62 * Average value Socket for Double-pole Single-side Stable P6B-26P PCB Mounting Holes (BOTTOM VIEW) Tolerance: ±0.1 mm 23.2 max. (23)* 11 max. (10.8)* 3.1 Six, 1.1-dia. holes 2.54 2.54 10.1 max. (10)* 7 (1.6) 3.5 0.8 10.16 7.62 0.4 (2.61) 10.16 7.62 7.62 * Average value ■Removal Tool ■Hold-down Clips ■Related Products P6B-Y1 P6B-C2 The G6B-4 Terminal Relay series with 4-point output is also available. For details, contact your OMRON sales representative. 10 G6B PCB Power Relay ■Approved Standards • The approval rating values for overseas standards are different from the performance values determined individually. Confirm the values before use. UL Recognized: (File No. E41643) Contact Coil ratings form Model Contact ratings 5 A, 250 VAC (General Use) 80°C G6B-1114P(-FD)(-1)-US G6B-1114C(-FD)-US 1 3 to 24 VDC 5 A, 30 VDC (Resistive) 80°C 1/8HP, 250 VAC 80°C 1/6HP, 250 VAC 80°C G6B-1174P(-FD)(-1)-US G6B-1174C(-FD)-US 1 3 to 24 VDC 8 A, 277 VAC (General Use) 80°C G6B-1184P-US 1 3 to 24 VDC 2 A, 250 VAC (General Use) 80°C G6B-2114P(-FD)(-1)-US G6B-2214P(-FD)(-1)-US G6B-2014P(-FD)-US G6B-2114C(-FD)-US G6B-2214C(-FD)-US G6B-2014C(-FD)-US CSA Certified: 6,000 1,000 30,000 8 A, 30 VDC (Resistive) 80°C 2 A, 30 VDC (Resistive) 80°C 5 A, 250 VAC (General Use) 80°C 2 Number of test operations 6,000 3 to 24 VDC 5 A, 30 VDC (Resistive) 80°C (File No. LR31928) Model Contact Coil ratings form Contact ratings 5 A, 250 VAC (General Use) 80°C G6B-1114P(-FD)(-1)-US G6B-1114C(-FD)-US 1 3 to 24 VDC G6B-1174P(-FD)(-1)-US G6B-1174C(-FD)-US 1 3 to 24 VDC G6B-2114P(-FD)(-1)-US G6B-2214P(-FD)(-1)-US G6B-2014P(-FD)-US G6B-2114C(-FD)-US G6B-2214C(-FD)-US G6B-2014C(-FD)-US 2 3 to 24 VDC G 6 B 6,000 1/6HP, 250 VAC 80°C 1,000 360 W, 120 VAC tungsten 80°C 6,000 8 A, 277 VAC (General Use) 80°C 30,000 8 A, 30 VDC (Resistive) 80°C 5 A, 250 VAC (General Use) 80°C 6,000 5 A, 30 VDC (Resistive) 80°C EN/IEC, TÜV Certified: Model 5 A, 30 VDC (Resistive) 80°C Number of test operations (Registration No. R50158246) Contact Coil ratings form Contact ratings Number of test operations 5 A, 250 VAC (cosφ = 1) at 70°C G6B-1114P(-1)-US G6B-1114C-US 1 5, 6, 12, 24 VDC 2 A, 250 VAC(cosφ = 0.4) at 70°C 5 A, 30 VDC (L/R = 0 ms) at 70°C 8 A, 250 VAC (cosφ = 1) at 70°C G6B-1174P(-1)-US G6B-1174C-US 1 5, 6, 12, 24 VDC 2 A, 250 VAC (cosφ = 0.4) at 70°C 8 A, 30 VDC (L/R = 0 ms) at 70°C G6B-2114P(-1)-US G6B-2214P(-1)-US G6B-2014P-US G6B-2114C-US G6B-2214C-US G6B-2014C-US 2 G6B-1114P-FD(-1)-US G6B-1114C-FD-US 1 5, 6, 12, 24 VDC G6B-1174P-FD(-1)-US G6B-1174C-FD-US 1 5, 6, 12, 24 VDC 20,000 5 A, 250 VAC (cosφ = 1) at 70°C 5, 6, 12, 24 VDC 1.5 A, 250 VAC (cosφ = 0.4) at 70°C 5 A, 30 VDC (L/R = 0 ms) at 70°C 3 A, 250 VAC (cosφ = 1) at 70°C 3 A, 30 VDC (L/R = 0 ms) at 70°C 5 A, 250 VAC (cosφ = 1) at 70°C 2 A, 250 VAC (cosφ = 0.4) at 70°C 5 A, 30 VDC (L/R = 0 ms) at 70°C G6B-2114P-FD(-1)-US G6B-2214P-FD(-1)-US G6B-2014P-FD-US G6B-2114C-FD-US G6B-2214C-FD-US G6B-2014C-FD-US 10,000 1.5 A, 250 VAC (cosφ = 0.4) at 70°C 2 5, 6, 12, 24 VDC 3 A, 30 VDC (L/R = 0 ms) at 70°C 11 G6B PCB Power Relay ■Precautions ● Please refer to “PCB Relays Common Precautions” for correct use. Correct Use ● Mounting • When installing more than two Relays side by side on a PCB, keep the gaps as shown below. It may cause a malfunction if heat is not dissipated smoothly from the Relay. ● Inhibit Circuit of the G6B-1177P(-FD)-ND-US Model • Do not use under conditions in which a surge is included in the power supply, such as when an inductive load is connected in parallel to the coil. Doing so will cause damage to the installed (or built-in) coil surge absorbing diode. Pitch: 2.54 mm × 2 min. between terminals Inductive load L G6B Coil ● Other precautions • The P6B model has a flux-resistant construction. Do not wash it down with water. • Perform wiring of No.1 and No. 2 of the X terminal as COM for doublewinding latching as shown below. The operation stability improves by doing this. Coil surge absorption diode Pitch: 2.54 mm × 2 min. between terminals • No specified mounting direction. ● Mounting Height of Sockets and Precautions G 6 B *17 mm max. 7 mm max. * 19.5 mm max. for G6B-1174P-FD-US, G6B-1174P-US models and 22 mm max. for G6B-1177P-FD-ND-US, G6B-1177P-ND-US models. • Hold-down clips (for mounting and removal) are also available.(For P6BC2 model) However, it is not suitable for G6B-1174P and G6B-1177P models. • Removal tool is also available. (For P6B-Y1 model) However, it is not suitable for G6B-1177P model. ● Using SPDT contact of the SPST-NO+SPST-NC Relay • Do not construct a circuit so that overcurrent and burning occur if the NO, NC and SPDT contacts are short-circuited with the SPST-NO+SPST-NC Relay.Arcing may generate short-circuiting between contacts if there is short-circuiting because of conversion to the MBB contact caused by asynchronous operation of the NO and NC contacts, the interval between the NO and NC contacts is small, or a large current is left open. 6 5 S R 1 2 COM • Check carefully the coil polarity (+ and -) of the Relay G6B-1177P(-FD)-ND-US. Do not reverse the polarity when connecting. Otherwise the built-in coil surge absorption diode may be damaged. • This Relay is a Power Relay which is suitable for power load switching. Do not use the G6B for signal purposes such as micro load switching under 10 mA. • Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product. • Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or equipment, and be sure to provide the system or equipment with double safety mechanisms. Note: Do not use this document to operate the Unit. OMRON Corporation Electronic and Mechanical Components Company 12 Contact: www.omron.com/ecb Cat. No. K021-E1-16 0118(0207)(O)
G6B-2014P-US DC5 价格&库存

很抱歉,暂时无法提供与“G6B-2014P-US DC5”相匹配的价格&库存,您可以联系我们找货

免费人工找货
G6B-2014P-US DC5
    •  国内价格
    • 1+11.42780

    库存:0

    G6B-2014P-US DC5
      •  国内价格 香港价格
      • 1+77.592911+9.40114
      • 10+40.2968710+4.88236
      • 50+35.6298150+4.31690
      • 100+32.52383100+3.94058
      • 500+31.90102500+3.86512
      • 1000+31.747341000+3.84650
      • 2000+31.439972000+3.80926
      • 4000+31.205414000+3.78084

      库存:0

      G6B-2014P-US DC5
      •  国内价格 香港价格
      • 1+77.584601+9.88140
      • 10+72.7101010+9.26060
      • 50+70.1912050+8.93980
      • 100+62.47120100+7.95650
      • 500+55.49760500+7.06830
      • 1000+47.602701000+6.06280

      库存:0